25 % off shipping on online purchases of CA$1,000.00 and more

inverter Fronius Galvo 2.5-1 regulier

$1,904.12 $1,713.70

In stock

SKU: 4,200,013,800

Add to cart

Description

inverter Fronius Galvo 2.5-1 regulier

INPUT DATAGALVO 2.5-1
Recommended PV Power (kWp)2.0 - 3.8
Max. input current16.1 A
Max. array short circuit current20.1 A
Nominal input voltage330 V
Max. input voltage (at 1000 W/m² / 14°F in
open circuit operation)
550 V
DC startup voltage185 V
Operating voltage range165 - 550 V
MPP voltage range165 - 440 V
Number of MPP trackers1
Admissable conductor size (DC)AWG 14 to AWG 6 (copper) ; AWG 6 (aluminium)
Number of DC input terminals3 x DC+ and 3 x DC- screw terminals for solid copper or aluminium and stranded / fine stranded copper
OUTPUT DATAGALVO 2.5-1
AC nominal output2,500 W
Max. output power2,500 VA
Max. output current 
208 V
13.7 A
220 V12.9 A
240 V11.8 A
Admissable conductor size (AC)AWG 14 to AWG 6
Max. output overcurrent protection20 A
Grid connection208 - 240 V
Frequency60 Hz
Frequency range59.3 - 60.5 Hz
GENERAL DATAGALVO 2.5-1
Dimensions (height x width x depth)24.7 x 16.9 x 8.1 in.
Weight36.93 lbs.
Degree of protectionNEMA 4X
Night time consumption< 1 W
Inverter technologyHF transformer
CoolingVariable speed fan
InstallationIndoor and outdoor installation
Ambient operating temperature range-40 to 122 F (-40 to 50 C)
Permitted humidity0 to 100%
Elevation11483 ft (3500m) with a max. input voltage of 430V
Certificates and compliance with standardsUL 1741-2010, UL1998 (for functions: AFCI, GFDI and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690, C22. 2 No. 107.1-01 (September 2001) , UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 -2013
EFFICIENCYGALVO 2.5-1
Max. efficiency96.0%
CEC efficiency95.0% @ 208 V / 95.0% @ 240 V
PROTECTION DEVICESGALVO 2.5-1
Overload behaviorOperating point shift, power limitation
2014 NEC ReadyIncluded
Photovoltaic Arc-Fault Circuit-ProtectionInternal AFCI Type 1 (Arc Fault Circuit Interrupter); in accordance with UL1699B Issue 2 -2013 and CSA TIL M-07 Issue 1 -2013
DC operation modesungrounded / neg. grounding / pos. grounding
DC Ground fault detector / interrupterInternal GFDI (Ground Fault Detector/Interruptor); in accordance with UL 1741-2010 and NEC 2014 Art. 690 (negative grounding)
External GFDI (Ground Fault Detector/Interruptor); in accordance with UL 1741-2010 and NEC 2011 Art. 690 (positive grounding)
DC disconnectIncluded
INTERFACESGALVO 2.5-1
Wi-Fi* / Ethernet LANFronius Solar.web / Fronius Solar.web, Modbus TCP, JSON
6 inputs or 4 digital inputs/outputsExternal relay controls
USB (A socket)Datalogging, inverter update via USB stick
2x RS422 (RJ45 socket)Fronius Solar Net
Datalogger and WebserverIncluded